Published on January 11, 2022
Oxycodone, Urine (Screen)
Specimen Type
| Test ID |
Refer to TOXICOLOGY SCREEN, URINE |
| EPIC ORDER |
Refer to TOXICOLOGY SCREEN, URINE |
| CPT Code(s) |
80307 |
| Group/Individual Test |
Individual |
| Laboratory |
Core Laboratory |
| Tube Station |
Routine: 30 STAT: 888 |
| Specimen |
Routine: |
10 mL Random Urine in Yellow Top Urine Tube (No Preservative/Additive); See important comments
10 mL Random urine in Sterile collection cup is acceptable if refrigerated.
|
| Micro: |
4 mL Random Urine in Yellow Top Urine Tube (No Preservative/Additive) |
| Stability |
Room Temperature: |
7 days |
| Refrigerated: |
30 days |
| Frozen: |
3 months |
| Availability |
24 hrs/day |
| Turnaround Time |
Routine: 2 hours STAT: 1 hour |
| Reference Range |
Cutoff Value: |
≤100 ng/mL |
| Comments |
Test should be used for screening and is intended for medical purposes only.
Oxycodone, Urine (Screen) is tested using the Siemens Atellica Oxycodone assay and is ordered as a component of the Urine Toxicology Screen. For confirmation, see Opiates Confirmation
For additional information related to drug screening, refer to the Urine Toxicology Chart. Screen components may vary by lab location.
|
Reviewed by J. Carr on January 02, 2026