Alert

Itraconazole

Tube Type = Blue Top or Red Bullet

Tube Type

Test ID LAB6712A
EPIC Order
ITRACONAZOLE
CPT Code(s) 80189
Group/Individual Test Group - group members: Itraconazole & (OH) Hydroxy-Itraconazole
Laboratory Special Chemistry Laboratory
Tube Station 30
Specimen Routine: 4 mL blood/Navy blue plain tube/Red plain tube also acceptable; See Comments
Micro: 1 mL blood/Red plain tube microtainer 
Stability


Room Temperature:

4 hrs Unspun

Refrigerated (2-8°C):

7 days Spun/Separated

Ambient: 

Not acceptable

Availability Routine: Three times/week - Monday, Wednesday, Friday; Not available STAT
Turnaround Time 4 days
Therapeutic Range
>0.5 mcg/mL (localized), >1 mcg/mL (systemic)
OH-Itraconazole: no established range
Comments
  • Off Site Collections: Centrifuge sample; aliquot serum (min volume 200 µl) & refrigerate within 4 hours of collection
  • Methodology: Liquid Chromatography Tandem Mass Spectrometry
  • Samples for Itraconazole testing must be received in the Core Laboratory by 1:00 pm for same day testing
  • Multiple test requests with same sample type will require additional volumes for testing
  • Pediatric microtainer devices available from Phlebotomy Services

Reviewed by J.Carr on November 14, 2025

UNC Hospitals
McLendon Clinical Laboratories
101 Manning Drive
Chapel Hill, NC 27514