Alert
In This Section

Available Tests

  • Complement C3, Fluid (C3, Fluid)

Complement C3, Fluid (C3, Fluid)

Test ID   LAB5143
EPIC Order
  C3 COMPLEMENT, FLUID
CPT Code(s)   86160
Group/Individual Test   Group
Laboratory   Core Laboratory
Tube Station   30; STAT: 888
Specimen Routine: 500 µl fluid; sterile container; No Preservatives; see important Comments
  micro: 300 µl fluid; No preservatives
Stability
Unspun: 2 hours
Room Temperature: Yes
Refrigerator: 30 days
Frozen: 1 month
Availability Routine: 24 hrs/day
  STAT: Yes
Turnaround Time   STAT:  1 hr; Routine:  2 hrs
Reference Range Normal: undefined
Comments
Provide fluid type and source.
Reference Range is not defined; therefore, other clinical data should be taken into consideration when interpreting these results.
 

INTERNAL REFERENCE TESTING SPECIMEN HANDLING INSTRUCTIONS:  

 

Centrifuge, aliquot, refrigerate

Reviewed by jrich on June 15, 2016

Note: Reference ranges provided on this web site are for guidance only, and may not reflect the most recent changes. Refer to laboratory reports for current reference data.

UNC Hospitals
McLendon Clinical Laboratories
101 Manning Drive
Chapel Hill, NC 27514

Top